Tag Structure and Group Code Basics ​

DXF is a tag-based text format that manages all data using numeric tags called "group codes".

1. How Group Codes Work ​

All data in a DXF file consists of pairs that "have one meaning in two lines".

  • Line 1: Group code (integer). Indicates what the next line represents.
  • Line 2: Value (string, number, etc.). The specific content corresponding to that group code.

Example: Specifying Layer Name ​

text
  8        <-- Signal indicating "this is a layer name"
Layer1     <-- Specific name

Why Use "Numbers" Instead of Strings? ​

Modern formats (JSON, XML) would write "layer": "Layer1", but computers in the early 1980s when DXF was born were very weak. For parsers (parsing programs), "reading one integer and judging" was much faster and saved memory compared to comparing long English words, which led to this number-based design.

2. Major Group Codes and Data Types ​

The "numeric range" of group codes strictly determines the type of data that follows (whether it's a string, decimal, or integer).

Code RangeData TypeMain MeaningMemory Hint
0StringEntity start declarationLINE, CIRCLE, SECTION, etc.
2StringNameSection names, block names, etc.
5StringHandleHexadecimal ID (unique serial number for objects)
8StringLayer NameRequired attribute
10, 20, 30Floating pointBase Point (X, Y, Z)10=X, 20=Y, 30=Z correspondence
40 - 48Floating pointNumeric valueRadius, height, scale, etc.
62IntegerColor NumberIndex color 1-255
100StringSubclass MarkerInternal type definition (R13 and later)
999StringCommentFree memo ignored by CAD

3. Writing Comments (Code 999) ​

DXF allows comments for humans to read.

text
999
This section was created by an auto-generation script

The line following code 999 is skipped by many CAD software. Useful for debugging or embedding custom metadata.

3. Binary DXF ​

In addition to the normal text format (ASCII), DXF has a Binary format to reduce file size.

Distinguishing ASCII and Binary ​

Check the first few bytes of the file.

  • ASCII: 0\nSECTION (or starts with BOM \xEF\xBB\xBF)
  • Binary: Starts with signature AutoCAD Binary DXF\r\n\x1a\x00.

Binary Format Structure ​

In Binary DXF, group codes and values are packed as binary data instead of text.

  • Group code: Usually 1 byte, or 2 bytes (R13 and later) integer.
  • Value: Stored directly as null-terminated strings, 8-byte floating point, integers, etc., according to the code's type.

When implementing a parser, you need to check this signature first and switch between "ASCII parser" or "binary parser."

4. Overall File Structure ​

DXF files consist of multiple SECTIONs. The order of sections is not strict, but the following order is recommended for AutoCAD compatibility.

5. Implementation Notes ​

  1. Fixed-precision text: In ASCII format, numbers are saved as text. Very long floating point numbers like 1.23456789012345 may appear, so be careful not to lose precision when parsing.
  2. Handling spaces: In older R12 format, it was standard to include 2 (or 3) spaces before group codes. Modern parsers generally perform strip() or trim(), but if you're making your own, you need to accept this "looseness."
  3. Omitting sections: Many viewers read files even without sections other than ENTITIES, but files without the EOF (End Of File) marker are often considered "broken."

Related: Section Overview | Glossary